- Contact Person : Ms. Wang Nancy
- Company Name : Shanxi Jerry Medical Instrument Co., Ltd.
- Tel : 0086-351-7036738
- Fax : 0086-351-7036740
- Address : Shanxi,Taiyuan,Room701/702, Pulse Oximeter, Patient Monitor, Dasheng Tech. Blg., 303Changzhi Road, Taiyuan City, Shanxi Province, China
- Country/Region : China
- Zip : 030006
Sell JERRY-III NIBP and SPO2 Patient Monitor
JERRY-III NIBP and SPO2 Patient Monitor
Parameters
Three parametersNIBP, SPO2, Pulse Rate.
Waveforms:
No waveform.
Features
1.Compact, light, easy for carrying and handling.
2.Large bright LED display of measurement, easy to read.
3.Unique character and icon display of information, easy for setting and watching.
4.Storage and review of NIBP and SpO2 data up to 800 groups.
5.Build-in rechargeable LI-battery for 10 working hours.
6.Low battery power indicator.
7.Automatic power-off.
8.Audio and visual alarm.
9.External printer available.
Applications
This product can be applied in the hospitals operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.
Standard Packing List
1. NIBPSPO2 Patient Monitor main unit 1pc
2. Adult finger SpO2 sensor 1pc
3. Adult NIBP cuff 1pc
4. Child NIBP cuff 1pc
5. NIBP extension tube 1pc
6. AC power adaptor 1pc
7. The operators manual 1pc
Selectable Accessory
Child finger/toe SpO2 sensor
Specifications
1. General Specifications:
Size: 205mm×200mm×95mm
Weight: 1 kg
Display Specification
Parameter Display: 7-segment LEDs
Information Display: Fixed characters and icons lighted by single-color LEDs
Power Supply Indicator: Dual-color LED
AC Power Adaptor
Input: 100-240VAC, 50/60Hz
Output: DC 9V,800mA
Battery
Lithium-ion rechargeable 5AHr 7.2V battery
Operating time: 10 hours with full battery capacity.
(Condition: 25, NIBP working period is 10 minutes.)
Recharge Time: 20 hours.
3.
Temperature
Working: 0 ~ 45 (°C)
Transport and Storage: -25 ~ 85 (°C)
Humidity
Working: 30% - 85 %
Transport and Storage: 30% - 95 % (no condensation
4. Monitoring Parameter
NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range: 0 - 300 (mmHg)
Pulse Rate Range: 30 - 250 (bpm)
Measurement Rage: Adult 30-255mmHg, Pediactri 30-160mmHg
Over-pressure Protection: Adult 300mmHg, Pediactri 220mmHg
Pressure Resolution: 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using end artery blood pressure measurement device.
SpO2%
Measuring Range: 35 - 99%
Resolution: 1 %
Accuracy: ±2 %(70% - 99%), unspecified (0% - 69%)
Pulse Rate
Measuring and Alarm Range: 0~250bpm
Resolution: 1bpm
Accuracy: ±1bpm
Storage Method: Store NIBP and SPO2 data each time after one NIBP measurement. Maximum Store Data of 800 groups.
5. Printer (optional)
Type: Thermal microprinter
Record Width: 57 mm
Recording Types: Real-time printing and review data printing
AC Power Adaptor
Input: 100-240V,50/60Hz
Output: DC 5V, 3A
Sell JERRY-III NIBP and SPO2 Patient Monitor