JERRY-III+ portable NIBP&SPO2(TEMP) Patient Monitor
JERRY-III+ Portable Tabletop NIBP&SPO2 Patient Monitor
Features
1. Intelligent monitoring NIBP,SPO2,PR,Pulse Strength,PLETH and TEMP;
2. Bright and clear LED and LCD display ;
3. Compact,light for handing and easy operation;
4. Audio and visual alarm when sensors off or alarm limit exceeded;
5. Storage and review of patients NIBP data up to 900 groups and SPO2,TEMP trend data up to 3150 groups.The data is never lost even when powers off;
6. Three kinds of power supply, AC Power, Build-in rechargeable Li- ion battery and Common AA alkaline or rechargeable batteries;
7. Automatic shut down,shut down time adjustable from 2~15Min ;
8. History data uploading to a personal computer for display,observing and printing.
Applications
This model can be applied in the hospitals operation room, ICU, clinic section office, Out-patient department, sickroom and emergency treatment.
Standard Packing List
NBIP/SPO2 Patient Monitor main unit 1pc
NIBP extension tube 1pc
Adult NIBP cuff 1pc
Adult SPO2 Sensor(include TEMP Probe) 1pc
AC power adaptor 1pc
Communication cable 1pc
The operators manual 1pc
Selectable Accessory:
Pediatric NIBP cuff
Pediatric SPO2 sensor
Specifications:
NIBP:
Patient: Adult and Pediatric
Measurement method: Oscillometric
RangeAdult:30mmHg~255mmHg Pediatric: 30mmHg~160mmHg
Measurement unite: mmHg/kPa selectable
Measurement mode: Manual, Auto, STAT
Measurement Type: SYS, DIA, MAP
Measurement interval in AUTO mode:1,2,3,5,10,15,20,30,45,60Min
Measuring period in STAT mode: 5 Min
Resolution1mmHg
Over-pressure protectionAdult:300mmHg Pediatric:220mmHg
SPO2
Patient: Adult, child
Range: 0 -100%
Resolution: 1 %
Accuracy: ±2 %(90~99%), ±3 %(70~89%),unspecified (<70%)
PR:
Range30bpm~250bpm
Resolution1bpm
Accuracy: ±2bpm
Temperature
Channel: 1
Input: Body surface thermal-sensitive resistor temperature sensor
Measurement Unit: °C /°F selectable
Range: 0~50
Resolution: 0.1
Accuracy: ±0.1
Environment
Temperature
Operation0°C~45°C
Transportation and storage-20°C~60°C
Humidity
Operation: 15%~95 %( non-condensing)
Transportation and storage: 10%~95% (non-condensing)
Altitude
Operation86kPa ~106kPa
Transportation and storage50kPa~106kPa
Power Requirements
AC power adaptor
Input: AC 100~240V, 50/60Hz, 0.7A
Output: DC 8.4V,1A
Internal battery
Type: 1500mAh/7.2V Li rechargeable battery
Operating Time: 5 hours of stand-by time with a full battery.
Recharge time: 8 hours
Dimension: 160mm×148mm×85mm
Net Weight: 565g