Handheld Multi-para.Patient Monitor

Handheld Multi-para.Patient Monitor
Product Detailed
Related Categories:Ward Nursing Equipments
1. ECG,SPO2,NIBP,Heart Rate,TEMP and PLETH 2. 2.2 inch Color OLED screen 3. tele-monitoring and remote monitoring by network

JERRY-I Color portable Handheld Mult-Parameter Patient Monitor

Which can measure ECG,SPO2,NIBP,Heart Rate,TEMP and PLETH

JERRY-I Color portable Handheld Mult-Parameter Patient Monitor

Features:

1. Palm, compact, easy for carrying and operation

2. Clear and bright color LCD with real time display

3. Friendly user interfaces with touch screen

4. Intelligent Measuring of ECG/NIBP/SpO2/PR/PLETH/TEMP

5. Storage/Review trend data up to 129 hours and 3888 groups

6. Utility PC software package for long time monitoring, web transferring, history data uploading/review/printing/storage.

7. Audio and visual alarm

8. Built-in rechargeable Li-ion battery, up to 5-hour power supply

9. Automatic shutdown for power saving

Specifications:

ECG

Input3- lead ECG cable, standard AAMI cable connector

Lead SelectionI,II,III

Gain Selection×1,×2,×4,×8

Sweep Speed: 12.5, 25, and 50 mm/s

Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)

Calibration Signal: 1mV square wave

Protection: Against electrosurgical interference and defibrillation

Heart Rate

Measuring Range: 30~250 bpm

Renew Time: 1 time per beat

Accuracy: ±1 bpm

Alarm Mode: Audible and visual alarm

SpO2

SpO2%

Measuring Range:0~100%

Resolution:1 %

Accuracy:±2 %(70%~99%), unspecified (0%~69%)

Pulse Rate

Measuring and Alarm Range:0~250bpm

Resolution: 1bpm

Accuracy: ±1bpm

NIBP

Method: Oscillometric

Mode: Manual, Auto, STAT

Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 60 (min)

Measuring Period in STAT Mode: 5 min

Cuff Pressure Range:0~300 (mmHg)

Pulse Rate Range:30~250 (bpm)

Measurement Rage: Adult 30~255mmHg, Pediatric 30~160mmHg

Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg

Pressure Resolution : 1mmHg

The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.

Temperature

Input: Body surface thermal-sensitive resistor temperature sensor

Measuring Range: 0~50

Accuracy: ±0.1